Fully-modulating, fully condensing, compact, sealed combustion, low NOx and up to 98% efficient.LAARS Heating Systems engineers designed the RHEOS+ boiler/water heater to provide ultra-high performance and superior efficiency. They are the ideal choice for demanding commercial jobs requiring 1.2 to 2.4 million BTU/hour. Seamless combustion modulation from 25 to 100 percent of full input maintains maximum efficiency and helps cut operating costs as much as 50 percent. The heart of every LAARS RHEOS+ boiler/water heater is the patented, double-row, copper-finned tube heat exchanger and a 48-row stainless steel economizer that maximizes water heating surface area. Coupled with a powerful stainless steel burner and an industrial grade gas control system, this design delivers the highest heat transfer per square foot of floor space available. With its compact through-the-door design, NOx emission levels of less than10ppm, and controls that automatically adjust boiler performance to meet the required heating load, the RHEOS+ is a truly innovative and virtually perfect breakthrough in commercial heating.

Specifications
Model (Size) 1200 1600 2000 2400
Input - High Fire 1,200 MBTU/h 1,600 MBTU/h 2,000 MBTU/h 2,400 MBTU/h
Output - High Fire 1,080 MBTU/h 1,440 MBTU/h 1,800 MBTU/h 2,160 MBTU/h
Input - Low Fire 300 MBTU/h 400 MBTU/h 500 MBTU/h 600 MBTU/h
Output - Low Fire 270 MBTU/h 360 MBTU/h 450 MBTU/h 540 MBTU/h
Electrical (Boiler) 120V/single phase/20A 120V/single phase/20A 120V/single phase/20A 120V/single phase/20A
Electrical (Pump) 120V/230V/single phase 120V/230V/single phase 120V/230V/single phase 120V/230V/single phase
Weight 1420lbs 1465lbs 1495lbs 1550lbs


Up to top

 

Standard Equipment
  • Water flow switch
  • Low water cutoff with test light and manual reset button
  • Manual reset high limit
  • High gas pressure switch
  • Low gas pressure switch
  • Air pressure switch
  • Low-fire start time delay
  • Modulation capabilities down to 25% of full fire
  • ASME CDS-1
  • Leak test valve
  • Manual firing valve
  • ASME 160 lb. w.p. heat exchanger
  • Less than 10ppm NOx
  • Pump mounted
  • Pump time delay (adjustable 0.1-10min.)
  • 75 psi relief valve (RHHH+)
  • 125 psi relief valve RHHV+
  • Temperature and pressure gauge
  • Indicator/status lights for: Power On, Call for Heat; Pre-Purge; Burner On; Ignition Failure
  • Selector switch for internal or external (0-10VDC) control
  • 100% lockout ignition control
  • Copper primary heat exchanger
  • Stainless steel secondary heat exchanger
  • Internal water mixing system to allow minimum 70°F water inlet

Optional Equipment
  • Factory-installed LON or N2 (Metasys) card for communicating inlet water temperature, outlet water temperature, mixing system temperature, extra temperature (user-chosen), low mixing system temperature alarm, burner on/off status
  • Cupro-nickel primary heat exchanger
  • Hard water pump (water heaters only)
  • Normally open vent valve
  • Alarm bell
  • Additional motorized safety valve with proof of closure
  • Additional solenoid safety valve
  • 200°F max temperature controls (KY Code)
  • Ignition module with three attemps (non-CSD-1)

 