Feedmister |
|
The Hurst
Feedmiser Automatic Return System provides
storage for water make-up and return
condensate from the system loop. The system
consists of an elevated tank mounted
boilers.
When equipped
with optional trim, the Feedmiser provides a
quality, heavy duty packaged unit fully
assembled and ready to install. These units
are factory assembled with pre-wired control
panel, and fully piped pumps along with all
the neccessary fittings and valves. Consider
the optional automatic steam preheater. When
incorporated into the system, feedwater
temperature can be maintained at 210° F. At
this high temperature, oxygen and carbon
dioxide are released, reducing corrosion
problems in the boiler and piping system.
Systems are available in single, dual,
triple and quad pump configurations and
custom orders are welcome.
-
Sizes 30 to 1,000 gallons (Larger Sizes
on Request) For all types of steam
boilers with pressures to 300 psig.
The following trim shall be factory
installed on each system:
- Automatic, internal float actuated
fresh water make-up valve assembly.
- Water gauge glass set with bronze
shut-off cocks and drain.
- Tank drain valve, brass gate.
- Bi-metallic water thermometer.
- Pump suction piping with shut-off
valve and strainer.
Typical optional equipment:
- Control panel with motor starters &
breakers.
- Pump function lights, selector
switches.
- Diffuser tube for extra high
temperature condensate return .
- High and low water level alarms.
- Pump alternator switches.
- Magnesium corrosion rod.
- Epoxy lining Manhole openings (200
gallon & larger).
- Electric solenoid valve make-up
water assembly. Steam operated feedwater
preheater.
- Discharge pressure gauges.
|
Up to top
|
Blowdown Seperators |
|
The HBC
Blowdown Separator is designed to take water
from the boiler during blowdown and reduce
it to atmospheric pressure for disposal. The
HBC Separator accomplishes this by
separating the subsequent flashed steam from
the hot water. As the blowdown enters the
vessel, it is forced into a centrifugal
pattern by means of a striking plate. The
steam is vented to the atmosphere through a
top connection. The HBC Separator is built
as per requirements Section VIII of the ASME
Code and stamped by the National Board of
Pressure Vessel Inspectors. The HBC Blowdown
Separator provides an economical means of
safe boiler blowdown.
The separator
includes a structural steel support stand
for mounting to foundation. Options
available are after cooler, manual cooling
valve assembly, automatic cooling valve
assembly, and exhaust heads.
HURST BLOWDOWN
SEPARATORS are built to Section VIII,
Division 1 of the ASME Code for 250 PSI
design pressure. (200 PSI design pressure
with 150# ANSI flanges) Blowdown separator
design pressure should be a minimum of 25%
of the boiler maximum allowable working
pressure (MAWP) as recommended by the
National Board.
|
 |
Up to top
We can only sell new Hurst boilers
inside our Indiana, Illinois, and Kentucky territory.
If you are located elsewhere, you will need to contact the
representative in your area for pricing.